H.02 · Hydrogeology
Infiltration Testing
Field-measured infiltration rates for LID systems, soakaway design, and stormwater management — because assumed values from published tables have no place in a permitted design.
Measured rates. Defensible designs.
Low impact development systems — bioretention cells, infiltration galleries, soakaways, and permeable pavement — only perform as designed when the underlying hydraulic conductivity is actually measured. Published values and soil-class defaults carry uncertainty ranges that span two to three orders of magnitude. That kind of error translates directly into an oversized footprint, a failed drainage approval, or a flooded basement two years after construction.
We conduct field testing at the depth and horizon that will actually govern infiltration — not the surface topsoil — and we design the test program around the regulatory criteria the approval authority will apply. Test results are reported as saturated hydraulic conductivity values with a design safety factor explicitly derived from your site variability and relevant municipal or provincial guideline.
We work at the scale of a single residential lot up to multi-hectare mixed-use sites, and we coordinate directly with the civil engineer of record so the measured values feed straight into the drainage model without translation errors.
TYPICAL PROJECT TYPES
- Residential subdivision drainage
- Commercial site LID design
- Bioretention cell sizing
- Soakaway pit design
- Permeable pavement subbase
- Green roof drainage layer
- Municipal right-of-way LID
- Stormwater permit applications
Design assumptions that cost you
Published hydraulic conductivity tables span three orders of magnitude for a given soil class. A simple field test eliminates that uncertainty and protects you at the permit stage.
Scope
What the program covers
- Single-ring and double-ring percolation testing (ASTM D3385)
- Falling head and constant head hydraulic conductivity tests (ASTM D5126)
- Borehole permeability testing (Lefranc / Hvorslev method)
- Test pit excavation and horizon logging at design depth
- Soil horizon characterization and grain size analysis
- Seasonal groundwater depth assessment
- Minimum separation distance to groundwater (City of Vancouver, Metro Vancouver, MMCD criteria)
- Design hydraulic conductivity with safety factor per municipal guideline
- LID feasibility assessment and site suitability recommendation
- Soakaway and infiltration gallery sizing parameters
- Integration with civil drainage model (direct coordination with EOR)
- Stormwater permit support and regulatory correspondence
Process
Four-step field program
-
01
Site assessment & test location selection
We review the proposed drainage design, civil grading plan, and any existing subsurface data to select test locations that represent the infiltrating horizon — not the surface organic layer. We confirm minimum separation distances to groundwater and identify any constraints (utilities, setbacks, existing structures) that affect test placement. A pre-field memo is issued so the civil team can plan around the test footprint.
-
02
Field testing
Test pits are excavated or auger holes advanced to the design infiltration depth. Pre-saturation is conducted according to ASTM methodology to eliminate capillary effects, then steady-state flow measurements are taken over multiple time intervals. We log soil stratigraphy at each location and collect disturbed samples for gradation confirmation. Groundwater depth is measured where relevant to the permit requirement.
-
03
Data analysis
Field measurements are converted to saturated hydraulic conductivity using the appropriate correction factor for the test geometry. We assess spatial variability across the site, calculate the design value using the safety factor prescribed by the applicable guideline (e.g., 0.5× for Vancouver, 0.25× for Metro Vancouver LID designs), and flag any locations where testing indicates infiltration is not viable.
-
04
Infiltration report
The signed and sealed report documents the test methodology, field logs, laboratory data, calculated hydraulic conductivity values, and recommended design parameters. We include the safety factor rationale, groundwater separation table, and a site suitability summary that the approval authority can act on directly. Where requested, we attend pre-application meetings with the municipality to present findings.
Deliverables
What you receive
- Signed and sealed Infiltration Assessment Report (PDF)
- Field test logs with time-drawdown data tables
- Soil stratigraphic logs for each test location
- Grain size analysis results (where collected)
- Calculated saturated hydraulic conductivity per ASTM method
- Design hydraulic conductivity with safety factor derivation
- Groundwater depth measurements and seasonal estimates
- Site suitability summary for infiltration-based LID
- Design parameters table ready for use in drainage model
- Regulatory compliance summary (applicable municipal guideline)
Related Services
Services that typically pair with this one
Infiltration testing is most often part of a broader stormwater or hydrogeology scope. These services frequently accompany or follow the infiltration program.